欧美色视频日本片免费,欧美真人性做爰一二区,国产色欲色欲色欲.WWW,中国无码人妻丰满熟妇啪啪软件

热门搜索: 硫酸角质素(KS)ELISA试剂盒(种属:鱼) 白介素6(IL6)ELISA试剂盒(种属:鱼) 鱼白介素10(IL10)ELISA试剂盒发货及时 斑马鱼白介素12BELISA试剂盒发货及时 兔载脂蛋白B(apo-B)ELISA试剂盒发货及时 兔孕酮(PROG)ELISA试剂盒发货及时 兔羟脯氨酸(Hyp)ELISA试剂盒发货及时 兔抗酒石酸酸性磷酸酶ELISA试剂盒发货及时 兔晶体蛋白α(Cryα)ELISA试剂盒发货及时 兔结缔组织生长因子ELISA试剂盒发货及时 兔基质金属蛋白酶9ELISA试剂盒发货及时 兔肺表面活性物质相ELISA试剂盒发货及时 CD206分子ELISA试剂盒(种属:小鼠) CC趋化因子受体6ELISA试剂盒(种属:小鼠) 阻抑素(PHB)ELISA试剂盒(种属:大鼠) 中性内肽酶;脑啡ELISA试剂盒(种属:大鼠)

技术文章/ Technical Articles

您的位置:首页  /  技术文章  /  人不对称二甲基精氨酸(ADMA)ELISA试剂盒 “仁捷生物”产品文献

人不对称二甲基精氨酸(ADMA)ELISA试剂盒 “仁捷生物”产品文献

更新时间:2019-08-27      浏览次数:1438

“仁捷生物”产品文献:Clinical Value of Asymmetrical Dimethylarginine Detection in Patients with Connective Tissue Disease-Associated Pulmonary Arterial Hypertension

-----------------------------------------------------------------------------------------------------------------------

 

Juan Liu , Qiang Fu, Lili Jiang, and Youlian Wang

Department of Rheumatology, Jiangxi Provincial People’s Hospital, Nanchang 330006, China

Correspondence should be addressed to Youlian Wang; 

Received 4 April 2019; Revised 29 May 2019; Accepted 27 July 2019; Published 14 August 2019

Guest Editor: Yan Yang

Copyright © 2019 Juan Liu et al.-is is an open access article distributed under the Creative Commons Attribution License, which

permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Objective. To evaluate the clinical value of serum asymmetrical dimethylarginine (ADMA) in patients with connective tissue

disease- (CTD-) associated pulmonary arterial hypertension (PAH). Methods. 88 patients with CTD were recruited between

December 2017 and August 2018 in Jiangxi Provincial People’s Hospital. Patients were further divided into two groups: CTD

without PAH (n = 45 cases) and CTD-with PAH (n = 43 cases), according to the pulmonary systolic blood pressure measured by

echocardiography. 40 healthy controls were also included (n =40 cases). -e clinical data, including laboratory examinations,

echocardiographic measurements, pulmonary function, and serum ADMA levels determined by enzyme-linked immunosorbent

assay, (ELISA) were collected. -e correlation between ADMA levels and the occurrence of PAH, pulmonary function, and other

laboratory indexes in CTD patients were analyzed. Statistical analyses were performed by SPSS (version 23); P < 0.05 was

considered statistically signifificant. Results. -e serum levels of ADMA in the CTD-PAH group were signifificantly higher than

those of the CTD-without PAH group and healthy control group (P < 0.05); the serum ADMA levels were (0.706 ± 0.153 μmol/L),

(1.015 ± 0.122 μmol/L), and (0.661 ± 0.113 μmol/L), respectively. -ere was no signifificant difffference between the CTD-without

PAH group and healthy control group (P < 0.05). Correlation analysis showed that serum ADMA levels were positively correlated

with sPAP and NT-proBNP and negatively correlated with DLCO% (r =0.802, 0.475, 0.585, P < 0.001). M*riate analysis

indicated that elevated serum ADMA levels increased the risk for the appearance of PAH in CTD patients (OR =57.460,

P < 0.001). Using the receiver operating characteristic (ROC) curve analysis, at the cutoffff level of 0.810 μmol/L, ADMA showed

good diagnostic effiffifficacy as follows: sensitivity was 97.7%, specifificity was 75.6%, and the area under the curve (AUC) was 0.947

(P < 0.001). Conclusion. Increased ADMA levels are independently associated with the presence and severity of PAH in CTD

patients. -e levels of ADMA in the serum may contribute to be a noninvasive indicator for early diagnosis of CTD-with PAH patients.

 

Blood samples for measurement of serum ADMA concentrations were naturally coagulated at room temperature for 20 minutes and centrifuged for about 20 minutes (3000 rpm), and the supernatants were stored in 1 mL aliquots at −80°C until further use. Concentration of ADMA was measured in serum samples by using an enzyme immunoassay ELISA kit provided by Shanghai Renjie Biotechnology Co., Ltd. The whole detection process was completed in strict accordance with the operating instructions. The absorbance (OD) was measured at 450 nm by using a Microplate reader, and each sample was duplicated.

 

ELISA试剂盒:人不对称二甲基精氨酸(ADMA)ELISA试剂盒 

 

产品货号:RJ11983

微信扫一扫

邮箱:2450868877@qq.com

传真:86-区号-传真号码

地址:上海市杨浦区铁岭路32号1519-10室

Copyright © 2024 上海仁捷生物科技有限公司版权所有   备案号:沪ICP备16052159号-1   总访问量:257631   技术支持:化工仪器网

TEL:17302193538

扫码加微信